Description
The Doyen Myoma Screw is a specialised gynaecological instrument used to engage, hold, and apply traction to uterine fibroids during myomectomy and related procedures. Its spiral working tip enters the fibroid and provides a firm point of control for manipulation or removal.
Salwan Surgicare is a surgical instrument manufacturer supplying Doyen Myoma Screws to hospitals, gynaecology centres, distributors, procurement companies, healthcare organisations, and OEM partners worldwide.
The instrument commonly features a strong shaft, a spiral or corkscrew-shaped working end, and a broad handle. The handle allows controlled rotation during insertion and provides a stable grip when traction is required.
Small and large patterns may be available to suit different fibroid sizes and operative requirements. Catalogue examples also include different overall lengths and T-handle configurations. The selected model should match the intended surgical technique and approved product specification.
Doyen Myoma Screw Uses
The Doyen Myoma Screw is used to grasp and manipulate uterine myomas during open gynaecological surgery. It is commonly associated with uterine myomectomy, where one or more fibroids are separated from the surrounding uterine tissue.
During use, the spiral tip is placed against the selected fibroid. Controlled rotation advances the tip into the tissue. Once secure engagement is achieved, the surgeon can apply traction to expose the operative plane and support dissection.
The instrument may also help stabilise a fibroid while the surgeon separates it from adjacent tissue. Firm control can improve access to the operative area and assist with the removal of the myoma.
Doyen patterns are available in different sizes. B. Braun catalogues both small and large versions for gynaecological use, while other suppliers describe the instrument as a traction device used during uterine myomectomy.
Benefits of the Doyen Myoma Screw
The spiral working end provides secure engagement with firm fibroid tissue. Therefore, the surgeon can apply controlled traction without relying only on external grasping forceps.
A broad handle supports steady rotation during insertion. It also provides useful leverage when the fibroid must be elevated, stabilised, or moved within the operative field.
The rigid shaft transfers movement directly from the handle to the working tip. As a result, the instrument offers controlled manipulation during different stages of the procedure.
Different lengths and spiral sizes provide flexibility for various surgical requirements. Hospitals can select a suitable pattern according to the fibroid size, surgical approach, and surgeon preference.
The simple one-piece design supports visual inspection and routine instrument care. Smooth external surfaces also help with cleaning and sterilisation under approved hospital procedures.
Applications
Common applications include:
– Open uterine myomectomy
– Fibroid traction
– Uterine fibroid manipulation
– Exposure during myoma dissection
– Stabilisation of firm uterine tissue
– Gynaecological surgery
– Obstetrics and gynaecology instrument sets
– Hospital operating departments
Key Features
– Spiral corkscrew-style working tip
– Strong and rigid shaft
– Broad or T-shaped handle
– Controlled rotational insertion
– Secure fibroid engagement
– Firm traction and manipulation
– Small and large patterns where available
– Different lengths where specified
– Smoothly finished surfaces
– Medical-grade stainless steel
– Suitable for approved sterilisation procedures
Material & Quality
The Doyen Myoma Screw is manufactured from medical-grade stainless steel selected for strength, durability, and resistance to corrosion under appropriate handling and reprocessing conditions.
Production focuses on spiral formation, tip consistency, shaft alignment, handle stability, structural strength, and surface finishing. Accurate spiral geometry supports controlled engagement with the selected tissue.
Each instrument is inspected for working-tip shape, shaft straightness, handle attachment, surface condition, and overall workmanship before packaging.
Available within our broader retractors range, the Doyen Myoma Screw provides a specialised solution for fibroid traction and uterine manipulation during gynaecological surgery.
Export-Ready Instruments
Salwan Surgicare supplies Doyen Myoma Screws to hospitals, gynaecology centres, distributors, procurement companies, healthcare organisations, and medical equipment dealers across Europe, the Middle East, Africa, East Asia, South Asia, North America, and South America.
OEM manufacturing, private labelling, customised instrument markings, and tailored packaging are available for qualified partners. Selected lengths, handle styles, and small or large working patterns may be supplied according to approved product specifications.
Secure export packaging helps protect the spiral tip, shaft, handle, and surface finish during storage and international transportation.